Selamat Datang di Indotrade.co.id
Masuk | Daftar
Anggota Prioritas Prioritas IndotradeTahun ke-16
PT. ALATLAB GLOBALINDO
http://indotrade.co.id/alatlab/
Informasi Kontak
Nama:

Tn. Zaenal Abidin [Penjualan]

E-mail:
Situs Web:

Pesan Instan:

Nomor Telpon:

Nomor telpon Tn. Zaenal Abidin di Jakarta

Nomor Ponsel:

Nomor ponsel Tn. Zaenal Abidin di Jakarta

Nomor Faks:

Nomor faks Tn. Zaenal Abidin di Jakarta

Alamat:

Head Office : 7th Floor Suite 0707A Patria Park, Cawang, Jakarta Timur. Marketing Office : Jl. Raya Pondok Gede no. 17B Kramat Jati, Jakarta Timur
Jakarta, Jakarta
Indonesia

Rata-rata Tinjauan Pemakai

Tidak ada ulasan untuk perusahaan ini

Menulis tinjauan
Bahasa :

Katalog Produk

CO2 Incubator NUAIRE, model NU-4750, USA
Jumlah Pesanan:
Cara PembayaranTransfer Bank (T/T)
Negara AsalAmerika Serikat

Keterangan

U.S. AutoFlow CO2 Incubator Series

The US AutoFlow NU-4750 offers laboratory technicians an incubator which virtually runs itself to dependably control the temperature and CO2 level. A solid-state single gas analyzer, with 32-bit digital accuracy, utilizes a filter correlation technique for non-dispersive infrared analysis of CO2. The measurement of CO2 is independent of humidity and temperature variations within the chamber

Features :
- Programmable Microcontroller Dependability
The US AutoFlow is run by a programmable microcontroller that samples input sensors, sets control outputs, makes corrections through the use of fuzzy logic, and displays status on the control panel. Ultra Smart ( US) " Fuzzy Logic" provides quick, accurate, adaptive control of all the incubators parameters: chamber temperature, CO2, O2, humidity and door temperature. Fuzzy logic tolerates environmental changes and component variation. It continually adjusts and improves to provide a " living" , exceptionally stable chamber environment.

- Relative Humidity Display and Control
The US AutoFlow NU-4850 has a relative humidity display and control system. The system controls from ambient to 95% relative humidity. The recovery time to 95% ± 2% is typically less than 10 minutes. The accuracy is ± 3% from any given set point.

Clear and Complete Information :
- Chamber Temperature, set point and actual
- CO2 Level, set point and actual
- Output and Alarm Status
- Water Jacket, low water level warning
- Chamber Door Ajar
- CO2 Infusion Status
- Tank Status
- System Alarm Condition Status
- Humidity [ model NU-4850] , set point and actual
- Oxygen [ model NU-4950] , set point and actual

HEPA Filtration System :
The US AutoFlow employs two separate capsule HEPA filters to minimize potential contamination problems within the chamber. After a door opening, the internal recirculation system will return the chamber to better than Class 100 air quality within 30 minutes.

Oxygen Display and Control :
The US AutoFlow NU-4950 has an O2 display and control system. The system controls from 21% [ ambient level] down to 2% . The recovery time from ambient to 5% ± 2% is typically less than 10 minutes. The accuracy is ± 1% from any given set point. The oxygen sensor is a fuel cell type and is unaffected by CO2, H2 or other various acidic gases.

Specifications
US Autoflow CO2 Laboratory Incubator Exterior Dimensions : NU-4950
Width : 313 ( 787.4)
Depth : 25 1/ 23 ( 647.7)
Height : 353 ( 889)

US Autoflow CO2 Laboratory Incubator Interior Dimensions : NU-4950
Width : 21 1/ 23 ( 546.1)
Depth : 213 ( 533.4)
Height : 25 1/ 23 ( 647.7)
Volume : 6.65 Ft 3 ( 188.5 L)